DRAGER JULIAN
Περιγραφή
Αποστολή σε Φίλο σας
Reviews
EΛΛΗΝΙΚΟ MENΟΥ
MODEL
|
Julian |
VAPORIZERS | |
Agents (DISINFECTION/STERILIZATION) |
ISOFLURANE |
Kind | Variable bypass |
Number (STAINING POSTS) | 2 |
Interlock | Yes |
BACKUP BATTERY | Yes |
Kind | Lead gel |
Use per charge, hr | 0.5 |
Service contract | Yes |
GAS CONNECTIONS | 3 - for more inforamtion please see comments.3 (O2, N2O, air) |
Oxygen concentration (MONITORS) | Yes |
Oxygen sensor type (MONITORS) | Galvanic cell |
RESPONSE TIME, sec (SCATTERED LIGHT) | <500 msec |
Co2 concentration (DISPLAY) | Yes |
Apnea alarm (MONITORS) | Yes |
N2o (Interference compensation) | Yes |
Anesthetic agent monitors (MONITORS) | Yes |
Anesthetic agents (MONITORS) | Sevoflurane, enflur- |
Auto id (MONITORS) | Yes |
Agent conc alarm (MONITORS) | Yes |
Pulse oximeter (MONITORS) | Optional |
Other monitors (MONITORS) | Airway temperature |
Other features (MANAGEMENT FUNCTIONS) | Stored trends log, |
Monitors (CONTROL PANEL) | |
Airway pressure alert (MONITORS) | Piezoresistive |
Where measured (MONITORS) | Absorber |
Over-pressure alarm (MONITORS) | Yes - for specified range please see comments.5-98 mbar |
Subatmospheric | |
PRESSURE ALARM | Yes |
Continuing press alarm (MONITORS) | Yes |
Low pressure/apnea (MONITORS) | Yes |
Other press alarms (MONITORS) | Sensor fault |
Expiration vol/flow (MONITORS) | Yes |
Oxygen sensor type (MONITORS) | Hot-wire anemometer |
Where measured (MONITORS) | Expiratory limb |
Apnea alarm (MONITORS) | Yes |
High/low min vol (MONITORS) | Yes |
Other expir alarms (MONITORS) | Flow sensor fault |
POWER NEEDED, VAC (MONITORS) | 90-265 |
OUTLETS FOR AUXILIARY DEVICES (RISE TIME, msec) | 2 |
GAS EVACUATION SYSTEM (PHYSICAL CHARACTERISTICS) | AGSS, vacuum/exhaust |
HYPOXIC MIXTURE ALARM (PHYSICAL CHARACTERISTICS) | Yes |
OXYGEN ALARM (PHYSICAL CHARACTERISTICS) | Yes |
PHYSICAL CHARACTERISTICS | |
DIMENSIONS (HXWXD) (RISE TIME, msec) | 135x 70 x 70 |
WEIGHT, kg (EXTERIOR DOORS) | 90 |
Shelves, cm (PHYSICAL CHARACTERISTICS) | 50x 50 |
Drawers, cm (PHYSICAL CHARACTERISTICS) | 1 |
Writing board (PHYSICAL CHARACTERISTICS) | 34x 34 |
INSTALLATION | Mobile |
AUTO RECORD KEEPER (PHYSICAL CHARACTERISTICS) | Optional |
AUTOMATIC VENTILATOR (PHYSICAL CHARACTERISTICS) | Yes |
BELLOWS (PHYSICAL CHARACTERISTICS) | Yes |
Size (STIMULATOR) | Adult/pediatric |
Kind | Descending |
Primary controls | |
Ventilation methods (PHYSICAL CHARACTERISTICS) | IMV, manual,spontaneous, PCV |
Tidal volume (MONITORED PARAMETERS) | Yes |
Range, cc (PHYSICAL CHARACTERISTICS) | 50-1,400 |
Frequency, bpm (PHYSICAL CHARACTERISTICS) | 6-60 |
Inspiratory flow, | |
L/min (WATER REQUIREMENTS,) | 5-75 |
I:e ratio (REGULATORS) | 1:4 to 2:1 |
Inspiratory pause | 0-50% of insp time |
Pressure-limit, | |
cm H2O (Pressure range,) | 10-70 |
Peep, cm h2o (CONTROLS) | 0-20 |
System checks (PHYSICAL CHARACTERISTICS) | Automated self-test, |
DISPLAYS (STAINING POSTS) | Yes |
Number (STAINING POSTS) | 1 |
Kind | EL |
Integrated (PHYSICAL CHARACTERISTICS) | Yes |
Interface w/others (PHYSICAL CHARACTERISTICS) | Yes |
ANESTHESIA DATA MANAGEMENT (PHYSICAL CHARACTERISTICS) | Optional |
SUCTION DEVICE (MONITORS) | Yes |
DATA INPUT | Rotary knob, |
PRIORITIZED ALARMS (PHYSICAL CHARACTERISTICS) | Warning, caution, |
GAS CYLINDER HOLDER (PHYSICAL CHARACTERISTICS) | 2(O2, N2O) |
OTHER SPECIFICATIONS (AIR SUPPLY) | Sample gas return |
FDA CLEARANCE (Interference compensation) | Yes |
CE MARK (MDD) (Interference compensation) | Yes |