Cardiocap/5
The compact, all-in-one,
critical care monitor
Features
• Integrated hemodynamic and airway gas monitor with
critical care dedicated software for critical care and medium-
acquity monitoring
• Proven intuitive user interface, including anesthesia-dedicated
menu logic and alarm philosophy, as in all Datex-
Ohmeda monitors
• Small-footprint bedside monitor with large 10.4 inch
color display
• Shows up to 6 waveforms with large numerics
• 4 user-confi gurable modes for care-specifi c
preconfi gurations
• Color-coded and prioritized alarms for critical care
• Waveform snapshot to store and recall waveform
samples for later analysis
• 24-hour graphical trends of all measured parameters
• 5- or 30-minute minitrends continuously on screen
for quick historical view
• Built-in back-up battery to handle sudden
power-down situations
Available options
• Integrated airway gases O2
• Compatible with Datex-Ohmeda Network and iCentral for
data continuity, monitor-to-monitor communication and
centralized viewing
• Two invasive blood pressures and 2nd temperature
Technical Data
General
Dimensions (WxDxH) 330 x 220 x 300 mm/
13.0 x 8.7 x 11.8 in
Weight F-MXG: <11.2 kg/24.8 lb
F-MX: <10.2 kg/22.6 lb
Power 100-240 VAC ±10%, 60/50 Hz
Back-up battery 15 minute minimum, charging
time typically 5h
Graphical trends 20 min, 1, 2, 4, 6, 8, 10, 12
and 24h
Numerical trends All parameters, sampled
every 5 minute and after
NIBP measurement
Alarms Adjustable high and low
limit alarms
Operating temperature +10° to +40°C/50 to 104°F
Storage and transport
temperature –10° to +50°C/14 to 122°F
Relative humidity 0 % to 85 % non-condensing,
in airway 0 % to 100 %
condensing
Atmospheric pressure 660 to 1060 hPa
(500 to 800 mmHg)
Safety standards IEC 60601-1 approved
CE marking according to MDD
directive 93/42/EEC
CSA C 22.2.No. 601.1 approved
UL2601-1 approved
Display
Display size and type 10.4 inch LCD active matrix color
Number of traces Up to 6
Display resolution 640 x 480 pixels
ECG
Number of channels 3
Number of leads 3 or 5
ST analysis 3 channels, continuous
Heart rate
Measurement range 30 to 250 beats per min (bpm)
Accuracy ±5% or ±5 bpm, whichever
is greater
Pacemaker
Pulse detection 2 to 500 mV
Pulse duration 0.5 to 2 ms
Impedance Respiration
Measurement method Measurement uses ECG
electrodes to measure the
impedance changes as a result
of breathing
Measurement range 4 to 120 breaths/min
Accuracy ±5% or ±5 resp/min
Pulse Oximetry (SpO2), Standard
Plethysmographic waveform/plethysmogram
Measurement method Red and infrared light
absorption SpO2
Measurement range
SpO2 40% to 100%
Pulse rate 30 to 250 bpm
Accuracy
SpO2 (±1SD) 100% to 80%, ±2 digits
80% to 50%, ±3 digits
Below 50%, unspecifi ed
Pulse rate ±5% or ±5 bpm
Note: Use only Oxytip+ sensors provided by GE. See the Cardiocap/5 User’s Guide for a
list of approved sensors. Refer to the sensor instructions for specific accuracy data.
Pulse Oximetry (SpO2), Datex-Ohmeda
Datex-Ohmeda enhanced oxygen saturation
(N-XOSAT option)
Plethysmographic waveform/plethysmogram
Measurement range
SpO2 1% to 100%
Pulse rate 30 to 250 bpm
Measurement accuracy
SpO2 (±1SD) 100% to 70% ±2 digits or
100% to 70%, ±3 digits under
clinical patient motion conditions,
Below 70% unspecifi ed
Pulse rate ±2% or ±2 bpm (whichever
is greater)
Note: The enhanced oxygen saturation (N-XOSAT) option and Oxytip+ sensors are
designed together as a system to ensure the highest clinical performance. Use only
Oxytip+ sensors provided by GE. See the Cardiocap/5 User’s Guide for a list of approved
sensors. Refer to the sensor instructions for specifi c accuracy data.
Non-invasive Blood Pressure (NIBP)
Measurement range
Adult 25 to 260 mmHg
Child 25 to 195 mmHg
Infant 15 to 145 mmHg
Invasive Blood Pressure (InvBP)
Measurement range -40 to 320 mmHg
Accuracy ±5% or ±2 mmHg
Transducer sensitivity 5 μV/V/mmHg, 5 Vdc,
max 20 mA
PCWP (Pulmonary Capillary Wedge Pressure)
Temperature
Measurement range 10° to 45°C/50° to 113°F
Probe type Compatible with GE probes only
Accuracy 25.0° to 45°C: ±0.1°C/
77° to 113°F: ±0.2°F
10.0° to 24.9°C: ±0.2°C/
50° to 76.8°F: ±0.4°F
Ordering Information
Monitor Frame and Type
Cardiocap/5 6051-0000-164
Hemodynamic frame F-MX 6050-0005-614
Hemodynamic frame with gas F-MXG 6050-0005-617
Software
Critical care software S-XCCA01 6050-0005-616
Parameter Options
Cardiocap/5
5-lead ECG, SpO2, temperature, NIBP and
impedance respiration.
Hemodynamic frame, F-MX
Optional built-in measuring parameters:
N-XP, Invasive Pressures (2 pressures,
and 2nd temperature) 6050-0005-939
N-XOSAT, Datex-Ohmeda enhanced
SpO2 option 6050-0005-917
Healthcare Re-imagined
GE is dedicated to helping you transform healthcare delivery
by driving critical breakthroughs in biology and technology.
Our expertise in medical imaging and information technologies,
medical diagnostics, patient monitoring systems, drug discovery,
and biopharmaceutical manufacturing technologies is enabling
healthcare professionals around the world discover new ways to
predict, diagnose and treat disease earlier. We call this model of
care “Early Health.” The goal: to help clinicians detect disease earlier,
access more information and intervene earlier with more targeted
treatments, so they can help their patients live their lives to the fullest.
Re-think, Re-discover, Re-invent, Re-imagine.
GE Healthcare
 
  
*
  
  
*

Για να επιβεβαιωθεί ότι η φόρμα έχει συμπληρωθεί από ένα πρόσωπο και όχι από αυτοματοποιημένο πρόγραμμα, παρακαλώ πληκτρολογείστε τους χαρακτήρες που βλέπτετε στην εικόνα.
Οι χαρακτήρες θα εμφανιστούν κεφαλαίοι στην οθόνη σας.

  Redraw

Χαρακτήρες: 

Φόρτωση...