Μηχανοϊατρική
 
Αρχική Σελίδα   |  Η εταιρία   |  Επικοινωνία   |   Χάρτης Αναζήτησης    

    Αναζήτηση:          
Σύνθετη αναζήτηση 
   Το καλάθι είναι άδειο
     · Στο καλάθι     · Ταμείο            
Αρχική Σελίδα    Προϊόνα    Ο Λογαριασμός μου    Στο καλάθι      Vouchers
  
   

ΑΝΑΙΣΘΗΣΙΟΛΟΓΙΚΑ

 

Σελίδες:   1 2    Range:
Ταξινόμηση ως πρός:    Προϊόν     Τιμή     Προκαθορισμένο    

DATEX E-NMT MODULE

[Τιμή κατόπιν επικοινωνίας]

E-NMT Datex Ohmeda Module parts for sale. USOC Medical sale & Repair E-NMT Datex Ohmeda Module. Neuromuscular Transmission (NMT) is the transfer of an impulse between a nerve and a muscle in the neuromuscular junction. NMT can be blocked by neuromuscular blocking agents – drugs which cause transient muscle paralysis and prevent the patient from moving and breathing spontaneously. Muscle relaxation is used during general anesthesia to enable endotracheal intubation and to provide the surgeon with optimal working conditions. In critical care, muscle relaxation is used during mechanical ventilation to minimize the patient’s work of breathing and to improve oxygenation.The level of neuromuscular block is routinely measured by stimulating a peripheral nerve, usually in the hand, and by evaluating the muscle response either visually or by touching the hand. The NMT module provides quantitative, automatic measurement of muscle response to a stimulus. The unique MechanoSensor quantifi es the evoked mechanical response by measuring the motion of the thumb by a piezoelectric sensor, which converts the physical motion to an electrical signal. This sensor is available for adults and for pediatric use.NMT measurement setup with MechanoSensor. Note the location of the electrodes. Use tape to tie the MechanoSensor securely on the patient’s hand. Traditional Electromyography (EMG) measurement with ElectroSensor is also available. A supramaximal stimulus is needed to ensure that all muscle fi bers are stimulated with suffi cient intensity and that reliable measurements are achieved during deep neuromuscular block. The NMT module automatically searches the current needed for the supramaximal stimulus, and maintains this current throughout the procedure. Train-of-four (TOF) is used as a standard stimulation mode. Four supramaximal stimuli are generated at 0.5 second intervals. Each stimulus in the train causes the muscle to contract. Please contact our customer service for further questions or concerns. Related Products
 

Aspect Medical Systems BIS A-2000 XP Platform Bispectral Index Anesthesia Monitor

[Τιμή κατόπιν επικοινωνίας]

BIS monitoring provides direct information about the effects of anesthetics and sedatives on the brain. The technology works by placing a BIS sensor on a patient's forehead to obtatin information from electrical brain activity, or EEG. The BIS monitor then translates this information into a single number from 100 (indication an awake patient) to 0 (indicating absence of brain electrical activity) that objectively represents each patient's level of consciousness. BIS monitoring thereby enables clinicians to minimize the risk of under and over-dosing of anesthetics and sedatives. Other vital signs, such as heart rate and blood pressure, do not correlate with depth of consciousness and are unreliable measures of adequate anesthesia and sedation.
 

Σελίδες:   1 2    Range:

Φόρτωση...